Application
This device is a High-Tech product of mechatronics, using advanced wireless transmission technology, the circuit control by micro-electronics, it transfer metrical information of mechanical water meter into electric signal, by wireless remote GPRS network , the water meters will copy all metrological data automatically. The water meter will measure the flow of water pipeline, instead of copy metering information indoor, the information will read by wireless transmission.
ZSL apply to new project or retrofit of old building.
Feature
Ø Using wireless transmission technology, do not need copy metering information indoor, while no need arrangement of wire. installation is simple and easy;
Ø The transmission distance of handheld meter readers >200m in open space;
Ø Three-stage router can extend transmission distance;
Ø Friendly software interface of upper computer;
Ø Real-time data reading, can be tiered price;
Ø Remote data transmission and post-paid valve control;
Ø Waterproof designed and even work underwater;
Ø ERFCU design, low power consumption;
Ø Modulation data transmission, copy single metering information within 1.5 s;
Ø Simple and rational construction design, battery can be replace;
Ø WOL(wake-on-lan), extend communication distance;
Ø Wamr Net (network routing protocol),keep data safety;
Metrological Data
Ø Broadband: 64MHz
Ø Power supply: 3.6V/3.3A/h lithium battery;
Ø Static power: 30μA
Ø Modulation schemes: FSK
Ø Transmission distance>200m
Ø Life of battery: >6 years
Dimension
Diameter (mm) |
L (mm) |
L1 (mm) |
Width (mm) |
H (mm) |
h (mm) |
D |
d |
Maximum Flow Q4(m³) |
Normal Flow Q3(m³) |
Transitional Flow Q2(m³) |
Minimum Flow Q1(m³) |
15 |
165 |
259 |
69 |
115 |
191 |
G¾ |
R½ |
3.125 |
2.5 |
0.05 |
0.03125 |
20 |
195 |
299 |
85 |
115 |
191 |
G1 |
R¾ |
5.0 |
4.0 |
0.08 |
0.05 |
25 |
225 |
345 |
119 |
100 |
176 |
G1-¼ |
R1 |
7.875 |
6.3 |
0.126 |
0.07875 |
/
Diameter (mm) |
L1 (mm) |
L2 (mm) |
L (mm) |
H (mm) |
Width (mm) |
Maximum Flow Q3(m³) |
Normal Flow Q3(m³) |
Transitional Flow Q2(m³) |
Minimum Flow Q1(m³) |
DN40 |
245 |
205 |
450 |
320 |
150 |
20 |
16 |
0.32 |
0.2 |
DN50 |
300 |
220 |
520 |
335 |
165 |
31.25 |
25.0 |
0.5 |
0.3125 |
DN65 |
200 |
220 |
440 |
335 |
165 |
50 |
40 |
0.8 |
0.5 |
DN80 |
225 |
300 |
525 |
375 |
200 |
78.75 |
63 |
1.26 |
0.7875 |
DN100 |
250 |
340 |
590 |
415 |
220 |
125 |
100 |
2.0 |
1.25 |
DN125 |
250 |
340 |
590 |
415 |
220 |
200 |
160 |
3.2 |
2.0 |
DN150 |
300 |
420 |
720 |
520 |
285 |
312.5 |
250 |
5.0 |
3.125 |
DN200 |
350 |
440 |
790 |
560 |
340 |
500 |
400 |
8.0 |
5.0 |
DN250 |
400 |
570 |
970 |
660 |
370 |
787.5 |
630 |
12.6 |
7.875 |
DN300 |
450 |
640 |
1090 |
700 |
445 |
1250 |
1000 |
20.0 |
12.5 |